• Follow us

Product Categories

Magnetic Level Transmitter--The world's first HART 7 Magnestostrictive level transmitter

Magnetic Level Transmitter--The world's first HART 7 Magnestostrictive level transmitter

Magnetic Level Transmitter The world's first HART 7 Magnestostrictive level transmitter-Magnetostrictive TransmittersISE Magtech Magnestostrictive level transmitters are highly accurate, precise and offer a variety of configuration options.

Description

Welcome to purchase discount source magnetic level transmitter from our company, which is one of the best China magnetic level transmitter manufacturers and suppliers.

Magnetic Level Transmitter
The world's first HART 7 Magnestostrictive level transmitter-Magnetostrictive TransmittersISE Magtech Magnestostrictive level transmitters are highly accurate, precise and offer a variety of configuration options. The magnetostrictive transmitter may be utilized as a direct insertion transmitter or externally mounted to a magnetic level indicator for non-invasive level control. Externally mounted to a magnetic level indicator, they are ideal in high-pressure, high-temperature applications.
In direct insertion service, the sensor probe with magnetic float(s) is inserted into a tank and as the float rises or falls with the fluid, the transmitter provides level output. For externally mounted service, the probe senses the float(s) inside the magnetic level indicator.
The magnetostrictive level transmitters are available with two-wire loop powered 4-20 mA output(s), or bus powered with digital signal output(s).

Features
1) The only Magneto with registered DD’s for HART and Foundation Fieldbus to IEC-61804-2
2) HART (Rev. 5.0), FF (ITK 4.6), AMS Aware, FISCO, FNICO
3) Sensor trim from anywhere in the loop with HART Measure Level, Interface and Temperature simultaneously
4) User friendly setup via self-promting menus
5) Continuous monitoring of instrument health via HART
6) Ideal for High Temp/Hi Pressure, Corrosive or “Dirty” service

Specifications

 Electronic Specifications 

Supply Voltage

13 to 36 VDC

Repeatability

.005% of full scale or .010 in.,
  whichever is greater

Non-Linearity 

.01% of full scale or .030 in.,
  whichever is greater

Level Sensor Accuracy 

.01% of full scale or .030 in.,
  whichever is greater

Analog Output

(1) 4/20 mA primary level

Resolution

.025% of full scale

Output

Primary level, (1) 4/20 mA
  optional digital outputs
  via HART for temperature
  or interface detection

Calibration 

Zero and span field adjustable
  with push buttons, HART
  and AMS

Advanced Diagnostics

With HART or AMS for
  troubleshooting

Dampening 

1 to 25 seconds (field adjustable via DISPLAY)

Operating Temperature
  (electronics)

-58 to 185° F (-50°C to 85°C)

Housing

Explosion proof, dual compartment,1/2-in NPT, epoxy coated
aluminum; stainless steel optional

Polarity Protection

Diode in series with the loop

Humidity Limits

SAMA PMC 31.1-5.2

Vibration Limits

SAMA PMC 31.1-5.3

RFI Limits 

SAMA PMC 31.1-20 to 1,000MHz up to 30V/m 

 Transmitter Sensor Tube 

Material

316 ss standard, optional
  Hastelloy, Monel, Kynar sleeve

Operating Temperature

Indicator type up to 750°F (399°C)
  Insertion type -50 to 300° F
  (-45 to 149° C) 

Max. Pressure 

2000 psig @ 300° F

Range 

12 in. to 30 ft.


Applications
1) Position Sensing
2) Sanitary Service
3) Valve Positioning
4) Inventory Control
5) Corrosive Process
6) Batching Processes
7) Underground Tanks
8) Primary level/Interface
9) Process Temperature and Level



If you have more interest, please send  your valuable inquiry to this email: postmaster@wtindustrialeqpt.com


Related Products

Feedback