• Follow us

Product Categories

Ultrasonic Transmitter--Rosemount 3100 Series Level Transmitters (3101 3102 3105)

Ultrasonic Transmitter--Rosemount 3100 Series Level Transmitters (3101 3102 3105)

Rosemount 3100 Series Level Transmitters (3101 3102 3105) The Rosemount 3100 Series Ultrasonic Level Transmitter is the reliable and cost-effective, non-contacting measurement solution from Emerson.

Description

Welcome to purchase discount source ultrasonic transmitter from our company, which is one of the best China ultrasonic transmitter manufacturers and suppliers.

Ultrasonic transmitter
Rosemount 3100 Series Level Transmitters (3101 3102 3105)
The Rosemount 3100 Series Ultrasonic Level Transmitter is the reliable and cost-effective, non-contacting measurement solution from Emerson. Time proven ultrasonic technology with advanced software and state-of-the-art electronics delivers high reliability in a wide variety of applications.  

Main features:
1)    Continuous non-contacting level measurement with no moving parts
2)    Standard Integral LCD and push buttons for simple setup and on-site programming
3)    Aluminum or polymer (glass-filled nylon) housing options
4)    Corrosion resistant PVDF wetted material
5)    Easy plant integration with 4-20mA ⁄ HART® output and PlantWeb support
6)    Temperature compensation with integral or optional remote temperature sensor
7)    Two-wire direct current (dc) loop-powered
8)    Wide operating range to 36 ft (11m)


Specification

Key Specifications

Measurement Principle 

Ultrasonic, time-of-flight

Measuring Range 

26 ft (8 m) for Rosemount 3101
36 ft (11 m) for Rosemount 3102 and 3105

Accuracy 
  (under reference conditions *)  

Rosemount 3101:
± 0.2 in. (5 mm) for <3.3 ft (1 m), 
± 0.5% of measured distance for >3.3 ft (1 m)
Rosemount 3102 and 3105:
± 0.1 in. (2.5 mm) <3.3 ft (1 m), 
±0.25% of measured distance for >3.3 ft (1 m)

Level Resolution

Better than 0.04 in. (1 mm)

Blanking Distance 

12 in. (0.3 m)

Display

Standard 4 ⁄ 5 digit display for configuration purposes

Output 

4-20mA for 3101 
4-20mA with superimposed digital HART® communication for 3102 and 3105

Output Variables

Level for 3101 
Level, distance, volume, or open channel flow for 3102 and 3105

Configuration Tools
(for 3102 and 3105 only)

AMS, Field Communicator, Rosemount 3490 Series   Universal Controller, or any other DD- or EDDL-compatible host

Enclosure (Body and Cover) Material 

Polyurethane-covered die-cast aluminum or 
Engineered polymer (glass-filled nylon) housing

Wet-side Material

PVDF

Ingress Protection

NEMA 4X, IP66 for aluminum housing 
(requires a suitably rated cable gland/blanking plug – not supplied)

IP 66/67 for glass-filled nylon housing 
(when using the supplied cable gland/blanking plug)

Hazardous Location Approvals 
(for 3105 only)

Intrinsic Safety (ATEX, CSA, IECEx, and FM)

* Temperature: 68 °F (20 °C), Pressure: 1013 mbar   (atmospheric pressure), Relative Humidity: 50%, calm and stable water   surface.

Application
This ultrasonic transmitter can be used in storage tanks, buffer tanks, open air application and open channel flow. Available now with an engineered polymer (glass-filled nylon) housing for corrosive, harsh environments. It is rugged, lightweight, and corrosive resistant.



If you have more interest, please send  your valuable inquiry to this email: postmaster@wtindustrialeqpt.com


Related Products